The infrastruxure 80kw installation and startup manual 9901467 covers the installation, startup, and configuration of an entire type b infrastruxure power and rack solution. I would like to replace the power module on our ups but im not quite sure how to do so as i havent been able to find a. Store the battery modules in a cool ambient temperature of symmetra lx uses a modular, redundant architecture that can scale power and runtime as demand increases or when higher levels of availability are required. This power module is designed for symmetra power array. In addition, intelligent battery management facilitates precisioncharging for. This power module has a hotswappable design for easy installation and ensures clean, uninterrupted power to protected equipment during power module replacement.
The symim5 symmetra lx intelligence module from apc features a modular design that considerably decreases the space required for ease of deployment in spaceconstrained environments. Symmetra s modular design provides redundant power in a single chassis for businesscritical applications in server rooms and network closets. Mar 28, 2018 power module fault exists apc symmetra lx duration. Inrow cooling is becoming one of the most common ways to cool large server rooms and data centres with a higher degree of efficiency compared to crac air conditioning units. Enables simple upgrades and replacements of the power modules. Vin, vout, vbyp status screen 2 %load assuming no redundancy percentage of the load in relation to the total capacity of all. Apc symim5 symmetra lx intelligence module dell usa.
If you are referring to a single phase symmetra lx, power array, 6 kva rackmount, this is definitely not a user upgradeable firmware. Replacing sypm2ku power module on apc symmetra rm 6kva. Symmetra lx tower installation 220230240 vac version v3. This 3,200watt4,000volt ampere power module allows users to immediately increase the maximum output power available from their symmetra ups units.
This apc symmetra lx power module features one fourwire hard connection for convenient output connections. If you disengage the bad battery from the ups, the beeping will stop until you get a replacement. This symim5 module is refurbished and comes with a one year replacement warranty. If using a power array or symmetra rm, the main intelligence module is in control when the orange led on the redundant intelligence module has extinguished. Service and support 24 hours a day, 7 days a week we provide the most extensive online how to ups battery replacement videos, faqs and knowledgebase to help. It is a base firmware revision internal to the system, not to the network cards. Performing total power off procedure for symmetra lx. Apc sypm4kp symmetra lx 4kva power module, apc two. Symmetra lx syaf16krmt power module battery replacement. Shop staples for apc symmetra lx sypm4kp 100120200208 v. Apc sypm4kp symmetra lx 4kva power module, 200208v. The symmetra 4 kva power module from apc provides effective lighting and surge protection.
Cd with software, documentation cd, installation guide, user manual, websnmp management card. Its comprehensive solutions, which are designed for both home and corporate environments, improve the manageability, availability and performance of sensitive electronic, network, communications and industrial equipment of all sizes. Apc symmetra lx power module sypm4kp the apc symmetra lx power module sypm4kp offers increased scalable power to the symmetra lx family of ups systems. Over the last 3 years, one of the power modules short circuited and started a fire in my computer room xmas eve day. Apc symmetra lx power module sypm4kp this 3,200watt4,000volt ampere power module allows users to immediately increase the maximum output power available from their symmetra ups units. The ups, extended run cabinets, and battery modules are heavy.
Apc sya16k16p symmetra lx ups tower modeltechnical specifications. The ups provides high availability through redundancy by allowing configuration with one more power module than necessary. Cd with software, documentation cd, installation guide, rack mounting support. Save with powerswap battery program for apc symmetra lx systems, sybt5 battery trays with new batteries installed for quick and easy replacement. Inrow cooling is an ideal solution for any data centre to consider with the crac units situated inrow with the racks it has a much shorter distance to travel to cool servers and networking gear. Engineered to deliver the highest level of business continuity possible, apc symmetra lx s modular, redundant architecture can scale power and run time as demand. Exit, refreshthis unit also had a failed battery module until we crowbarred the module out of the frame. The status screens display information regarding load, battery, power module, voltage, and current. Apc symmetra lx 4kva power module, 200208v apc jamaica.
The apc symmetra px is a world class, redundant, scalable, power protection system designed to cost effectively provide high levels of availability. Feb 28, 20 power module fault exists apc symmetra lx duration. Lot 10 block 16 phase iv peza, rosario cavite, philippines. This module features an output power capacity of up to 4 kva 3. Power modules power module 1 x hardwired receptacles 220 v ac input voltage 3200 w output power 5. Apc sybt5 battery module with brand new batteries plug. Apc symmetra lx battery module with flameretardant case. Symmetra lx is a redundant online double conversion ups. Apc symmetra px 500kw static switch module sysw500kd.
Symmetra lx rackmount ups symmetra lx tower ups complete pre installation checklist check that the circuit breaker to be used to power the ups is in the off position. Cd with software, installation guide, user manual, websnmp management card. They are labeled as such and the main resides in the lower bay. With all these features it is an ideal product for you. Tutorial for hotswapping the sypm2ku power module of the apc symmetra rm 6kva modular, redundant, and scalabale ups system.
The symmetra rm brings the proven and patented symmetra power array technology in a rackmountable form. Apc sypm4kp symmetra lx 4 kva 200v208v power supply module. Highly available, redundant and scalable doubleconversion online power protection, the apc symmetra lx is the first ups with redundancy and scalability within a single chassis. This procedure supplies power to the symmetra lx and does not supply. Apc symmetra lx power module ups plugin module ac 200208240 v 3. Hello, we have a symmetra lx syaf16krmt which is no longer listed in apcs site. When the load is greater than this threshold, an alarm will sound. All electrical power and power control wiring must be. Build a pc apc symmetra lx ups question techspot forums. Ensure that all modules power, battery, and intelligence are fully installed. Based on the value entered we will estimate the run time that you will have during a total power outage. Symmetra lx will indicate which intelligence module is in control by illuminating an additional green led on the far left of the led array. Copyright, intellectual, and all other proprietary rights in the content including but not limited to software. Apc symmetra lx fault beeping solutions experts exchange.
Apc symmetra lx 12kva ups power and racks sya12k16p. High density, doubleconversion online power protection with scalable runtime. Cd with software, documentation cd, installation guide, user. Identify the faulty power module using the display interface. Enter the total load power draw of all devices to be protected by the ups here. Engineered to deliver the highest level of business continuity possible, the symmetra lx uses a modular, redundant architecture that can scale power and runtime as demand increases or when higher levels of availability are required.
Replacing an apc power module is very simple, and covered in this youtube video. On the battery module, turn the black loching key in the center uo the unlock position, the using the little lip on the battery, lift and pull towards you. With more servers, storage products and other missioncritical it equipment becoming rackbased, the need is increasing for high availability innovative rackbased power solutions. Physical installation symmetra lx physical installation. Symmetra lx rackmount ups symmetra lx tower ups 9901539b001, 042006 important safety and installation instructions this manual provides instructions on the wiring and connections for the symmetra lx tower and rackmount ups. The following instructions describe the process to successfully replace a power module. To fully power down the ups, turn off the system enable switch, and open the input circuit breaker. This unit can be used either as a single phase or as a 3 phase unit, without any adjustments or changes being made to system to achieve this. Breaffy rd industrial estate castlebar, ireland or american power conversion 40 catamore boulevard east providence, rhode island, 02914, usa or american power conversion a.
Shop for apc symmetra upss at falcon technologies 6400 watts8000 va, input 208voutput 120v, 208v, interface port db9 rs232, smartslot, extended runtime. A flexible range of power capacity options can configure to give 120208 or 120240 output voltages for different needs, while a plugandplay design takes the guesswork out of installation. Apc symmetra lx 12kva ups engineered to deliver the highest level of business continuity possible, the symmetra lx uses a modular, redundant architecture that can scale power and runtime as demand increases or when higher levels of availability are required. Check that the input circuit breaker on the ups is in the off position. Infrastructure and connectivity surge protection and power conditioning uninterruptible power supply ups. Cd with software, documentation cd, installation guide, rack mounting support rails. All of our apc sybt5 plug and play ups replacement battery modules ship with brand new factory fresh batteries installed. Non lx systems such as power array and symmetra rm 12kva and 6kva systems have dedicated main and redundant intelligence modules. Symim5 apc symmetra lx main intelligence module refurbished. Out of the box, wordpress includes six different user roles.
Industrys most spaceoptimized modular ups solutions. Do not install the battery modules in the frame until you are ready to power up the symmetra rm. In addition, intelligent battery management facilitates precisioncharging for optimum battery performance, life and reliability. Each item comes with reusable packaging for easy recycling. Rated 5 out of 5 by lenbrown from bad design i have the symmetra lx with these power modules. Symmetra lx load electrical installation guide electrical. Switch on the circuit breakers for all connected equipment. Before beginning the electrical installation, perform the following procedures. Apc symmetra lx 4kva power module, 220230240v indonesia select your location.
Modular power revitalization service mprs for symmetra lx. Seamlessly integrating into todays stateoftheart data center designs, the symmetra px is a true modular system. Also, empty power module bays may be populated with power. Techspot is dedicated to computer enthusiasts and power users. Apc symmetra lx 4kva power module, 200208v apc usa. The schneider electric critical power and cooling solutions cpcs modular power revitalization service mprs for symmetra lx provides a comprehensive onsite ups refresh service for modular singlephase ups systems. Each symmetra power module is rated at 4 kva so when the symmetra lx is fully populated with 5 power modules, it can draw u p to16 kva from the utility as one power module is redundant. Remove your old module and replace it with this new one. The 80kw utility connection instruction sheet 9901469 provides specific instructions for the electrician connecting power to the pdu with system bypass.
Replacing symim5 intelligence module on apc symmetra lx. Adding run time increases availability by allowing the system to operate through longer outages without shutting down. Check that the powerview is connected to the primary intelligence module im. Batteries can be permanently damaged if loaded prematurely. Status screen 1 vin, vout, iout the input voltage v, output voltage v, and output current a for each phase. Buy apc sybt5 symmetra lx battery module with fast shipping and toprated customer service. Powerswap for apc symmetra lx ups platforms refurbups. A small footprint, modular, redundant architecture, integrated ups tower system designed for businesscritical applications in server rooms and network closets with a 16kva output. Apc symmetra power module power supply hotplug redundant plugin module ac 200208230240400 v 2800 watt product information product dimensions. Do not install battery modules until you are ready to power up the ups. Intelligence module is the backup brain and ensures faulttolerance. Symmetra rm meets this need with scalable, redundant units. Apc sya16k16p symmetra lx ups tower data sheet technical. The symim5 is the intelligence module that works with the apc symmetra lx series of power arrays.
Proper procedure for replacing the intelligence modules in. All electrical power and power control wiring must be installed by a qualified. American power conversion corp manufacturer part number. Assign the ip using the software, then connect to it via web browser and configure. Apc sets the standard in its industry for quality, innovation and support. Hotswappable, user replaceable power, battery, and intelligence modules enables low mttr and ease of service. It also provides fast serviceability and reduced maintenance requirements via selfdiagnosing, fieldreplaceable modules.